Slide Mounting Media
- (30)
- (1)
- (1)
- (1)
- (4)
- (2)
- (1)
- (1)
- (2)
- (1)
- (16)
- (2)
- (1)
- (1)
- (3)
- (2)
- (1)
- (3)
- (1)
- (2)
- (8)
- (5)
- (2)
- (17)
- (5)
- (2)
- (1)
- (1)
- (1)
- (2)
- (2)
- (3)
- (3)
- (2)
- (9)
- (1)
- (1)
- (2)
- (1)
- (16)
- (2)
- (9)
- (12)
- (1)
- (2)
- (23)
- (1)
- (9)
- (2)
Filtered Search Results

Electron Microscopy Sciences SEM Low Voltage Resolution Specimen Gold on Carbon, Hitachi Stub
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Larger gold particles in this test allow for a higher contrast and smaller gaps allow resolution to be measured. This helps to make the test easier to use when operating conditions are not optimal.
Type: Hitachi Stub

Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences Roto Shake Genie Magnetic Mounting Strip for Bag, 16/Bag
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Accessory for the Enviro-Genie 6-in-1 and Roto-Shake Genie 6-in-1.

Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences Technovit 7100 Histo Set
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Foils, 100 pieces Histobloc, Histoform S or Q Embedding Mold, 100 piece Histoknife H, microtome knife holder, 17 or 22 cm, Technovit 3040, 100g powder and 80 ml liquid.

Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences Citifluor™ Mountant Solution PVP-1, Glycerol Free, Hardening 25 ML
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Citifluor mounting medium for immunofluorescence is designed to reduce the fading of the fluorescence of dyes used for labeling biological specimens. In the technique of fluorescence microscopy, the fluorescence is stimulated by high intensity UV and/or visible light. Absorption of the light populates an excited state of the dye (usually a singlet state) and this leads to fluorescence. However, the excited state of the dye may undergo chemical reaction, which leads to destruction as evidenced by the fading of the fluorescence and consequent loss of the image. Aqueous solution of poly(vinyl pyrrolidone).
Material: Glycerol Free
Type: Hardening

Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences EMS Glycerol Mounting Medium 100 ML
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
This aqueous mounting medium made with glycerol is for preserving fluorescence of tissue and cell smears. It is excellent for preserving thick sections that can not be mounted with mounting medium or fresh frozen tissues containing lipids, e.g. brain tissue.
This mounting medium is also useful for immunofluorescence. This unique formula prevents rapid photobleaching of FITC, Texas Red, AMCA, Cy dyes, Alexa fluoro 488, Alexa fluoro 594, Green fluorescent protein (GFP), tetramethyly rhodamine and Redox. The fluorescence is retained during prolonged storage at 4 degree C in the dark. This medium does not contain phenylenediamine, which destroys immunofluorescence of Cy dyes.
Not recommended for phycoethyrin (PE), phycocyanin (PC) and allophycocyanin (APC).
Reagent: Ready to use mounting medium for IHC and immunofluorescence (IF).
Refractive Index: 1.472. Storage at temperature of 2-8 degree C is recommended. Protect from light.

Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences Citifluor™ Mountant Solution PVP-1+Antifadent, Glycerol Free, Hardening 25 ML
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Citifluor mounting medium for immunofluorescence is designed to reduce the fading of the fluorescence of dyes used for labeling biological specimens. In the technique of fluorescence microscopy, the fluorescence is stimulated by high intensity UV and/or visible light. Absorption of the light populates an excited state of the dye (usually a singlet state) and this leads to fluorescence. However, the excited state of the dye may undergo chemical reaction, which leads to destruction as evidenced by the fading of the fluorescence and consequent loss of the image. Aqueous solution of poly(vinyl pyrrolidone) containing an amine-based antifadent.
Material: Glycerol Free
Type: Hardening

Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences EMS Glycerol Mounting Medium w/ DAPI & DABCO 20 ML
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
EMS Glycerol with DAPI and DABCO is an aqueous mounting medium for preserving fluorescence of tissue and cell smears. It prevents rapid photobleaching of FITC, Texas Red, AMCA, Cy2, Cy3, Cy5, Alexa fluoro 488, Alexa fluoro 594, Green fluorescent protein (GFP), tetramethyly rhodamine, Redox. Fluorescence is retained during prolonged storage at 4 deg C in the dark.
This mounting medium is fortified with DAPI which is a counter-stain for DNA. This product is to be used in situ hybridization techniques or other methods where fluorescence of DNA staining is required. DAPI excites at 360nm and emits at 460nm, producing a blue fluorescence. RNA is also stained with DAPI.
Not recommended for phycoethyrin (PE), phycocyanin (PC) and allophycocyanin (APC).
Reagent: Ready to use mounting medium with anti-fading agent
Refractive Index: 1.4617

Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences Citifluor™ Mountant Solution MWL4-88, Glycerol Based, Hardening 25 ML
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Citifluor mounting medium for immunofluorescence is designed to reduce the fading of the fluorescence of dyes used for labeling biological specimens. In the technique of fluorescence microscopy, the fluorescence is stimulated by high intensity UV and/or visible light. Absorption of the light populates an excited state of the dye (usually a singlet state) and this leads to fluorescence. However, the excited state of the dye may undergo chemical reaction, which leads to destruction as evidenced by the fading of the fluorescence and consequent loss of the image. Mountant solution based on Mowiol 4-88, glycerol, water and tris-amine buffer.
Material: Glycerol Based
Type: Hardening

Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences EMS Glycerol Mounting Medium w/ DABCO 30 ML
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
EMS Glycerol with anti-fading agent 1, 4-Diazobicyclo-(2,2,2-octane (DABCO) is an aqueous mounting medium for preserving fluorescence of tissue and cell smears. This unique formula prevents rapid photobleaching of FITC, Texas Red, AMCA, Cy2, Cy3, Cy5, Alexa fluoro 488, Alexa fluoro 594, Green fluorescent protein (GFP), tetramethyly rhodamine, Redox. Fluorescence is retained during prolonged storage at 4 degree C in the dark. Not recommended for phycoethyrin (PE), phycocyanin (PC) and allophycocyanin (APC).
Application: Immunofluorescence, confocal microscopy.
Reagent: Ready to use mounting medium with anti-fading agent.

Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences Permount™ Mounting Medium 100 ML
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Permount is a toluene-based synthetic resin mounting medium that is ideal for rapid mounting and long term storage of slides. Its low viscosity allows for a thinner mounting layer offering better optical quality and bubble-free preparations. It has a refractive index near that of a fixed protein which helps to keep images free of distortion. Use for mounting coverslips to slides with thick or thin specimens. Permount preserves most biological stains with little or no fading when the slides are stored in darkness. It contains an anti-oxidant to prevent the formation of annular rings and its high softening point (155 degree C/311 degree F) makes it suitable for microprojection.

Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Revvity Health Sciences Inc DAPI
DAPI

Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
MSC EZ-FILL MOUNTING BRACKET
5L CHR PLT EZ-FILL MOUNTING BRACKET

Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences CytoSeal™ Mounting Medium 60 Mounting Medium 16 OZ
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
CytoSeal 60 and 280 are toluene-based mounting mediumformulated from acrylic resins that will not crack or discolor with age. An antioxidant has been added to the formulation to inhibit fading or yellowing of stained specimens. It will not become brittle and crack, nor will it discolor or yellow with age. CytoSeal can be dissolved in toluene or xylene. Low-viscosity medium dries quickly and spreads evenly and rapidily virtually eliminating air bubbles.

Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences CytoSeal 60, 4 oz
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Premium quality; formulated from the highest quality advanced acrylic resin. It will not become brittle and crack, nor will it discolor or yellow with age. CytoSeal dries rapidly, allowing examination soon after application. It can be used with oil immersion objectives and in fluorescent procedures. Slides will not stick together and the medium will not "cold flow" to the edge of the slide during long term storage. CytoSeal can be dissolved in toluene or xylene. An antioxidant has been added to the formulation to prevent fading of slides. CytoSeal comes in a Controlled Drop Dispenser, with varying viscosities. CytoSeal 60, which has a viscosity of 60cps, is intended primarily for use with cover glass.

Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
AdipoGen DAPI 2HCl Solution 10mM water
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Chemical. CAS 28718-90-3. Formula C16H15N5 . 2HCl. MW 350.25. DAPI 4,6-Diamidino-2-phenylindole dihydrochloride is a cell permeable, fluorescent dye that is a minor groove-binding probe for DNA. Binds to the minor groove of double-stranded DNA preferentially to AT rich DNA, forming a stable complex which fluoresces approximately 20 times greater than DAPI alone. DAPI is several times more sensitive than ethidium bromide for staining DNA in agarose gels. It may be used for photofootprinting of DNA, to detect annealed probes in blotting applications by specifically visualizing the double-stranded complex, and to study the changes in DNA and analyze DNA content during apoptosis using flow cytometry. DAPI staining has also been shown to be a sensitive and specific detection method for mycoplasma. Spectral Data Excitation lambdaex 340 nm Emission lambdaem 488 nm only DAPI. Excitation lambdaex 360nm Emission lambdaem 460nm DAPI-DNA complex.

Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More